To connect the gas pressure regulator to the LP cylinder, please follow these steps:
1. Make sure the LP cylinder is turned off by turning the hand wheel clockwise until it stops.
2. Place the LP cylinder under the gas grill body with the valve facing outward.
3. Ensure all burner controls are turned to the OFF position.
4. Remove the safety cap from the cylinder valve.
5. Center the regulator xxxx into the cylinder valve.
6. Turn the coupling nut clockwise until it stops. Hand tighten only, do not use a wrench.
It is important to note that you should only use the gas pressure regulator provided with the grill. This regulator is set for an outlet pressure of 11 inches water column. Make sure to perform a leak test before using the grill for the first time or if the cylinder has been changed. If you encounter any issues, it is recommended to contact customer service for assistance.