Answer

Apr 29, 2025 - 12:07 PM
To install the Husky 1216503 Pressure Activated Conventional Farm Consumer Pump Nozzles, follow these steps:
1. Turn off the dispenser and relieve the line pressure.
2. Use pipe thread sealant (not Teflon tape) approved for gasoline on the male threads of the hose section.
3. Tighten the nozzle approximately 1 to 2 turns past hand tight, making sure not to overtighten.
4. Pressurize the system and visually inspect for any leaks.
5. Test the nozzle for proper automatic shut off between 5 - 10 gpm / 18.9 - 37.9 Lpm.
It is important to follow these installation instructions to ensure proper functioning of the nozzle and to prevent any potential leaks or accidents.