Answer

Apr 28, 2025 - 12:20 PM
To clean the titanium cell, follow these steps:
1. Turn off the filtration system and close off the necessary valves.
2. Remove the cell from its support.
3. Place the cell in a solution of 3% hydrochloric acid (1 liter of acid for each 10 liters of water) for no more than 10 minutes.
4. Once the incrustations have softened, remove them by rinsing the cell with a hose.
5. Do not use metallic or sharp objects to remove incrustations, as this can damage the cell.
6. After cleaning, reassemble the cell and reinstall it in its support.
It is important to note that scratching the edges or surface of the cell can make it vulnerable to chemicals, deteriorate the cell, and cancel the warranty. It is recommended to carry out a monthly visual inspection of the cell and clean it as necessary.
Add New Comment