To set the low and high voltage limits on the ALLOYSEED DC 12V Low Voltage Protection Module for Battery, follow these steps:
1. Make sure the module is not powered on.
2. Long press the S1 button.
3. While holding the S1 button, supply power to the module.
4. The screen will display "---" to indicate that you have entered the setting mode.
5. Press the S1 button to enter the high limit setting. The screen will display "H --".
6. Use the S2 button to adjust the value of the first digit. Each press of the S2 button will cycle through the numbers 0-9.
7. Press the S1 button to move to the next digit and adjust its value using the S2 button. Repeat this step for the third digit.
8. Press the S1 button to save the high limit setting and return to the initial screen.
9. To set the low limit, the screen will display "L --". Press the S1 button to enter the low limit setting.
10. Follow steps 6 and 7 to adjust the value of the low limit.
11. Press the S1 button to save the low limit setting and return to the initial screen.
12. To select the working mode, the screen will display "P --". Press the S1 button to enter the mode selection.
13. Use the S2 button to cycle through the different working modes (100-108).
14. Press the S1 button to save the mode selection and return to the initial screen.
15. To activate or deactivate the screen display, the screen will display "F --". Press the S1 button to enter the screen activation.
16. Use the S2 button to switch between 0 and 1. 0 turns off the digital tube display, and 1 turns it on.
17. Press the S1 button to save the screen activation setting and return to the initial screen.
18. If you need to fix any bugs, the screen will display "C --". Press the S2 button to display "X".
19. Press the S1 button to save the bug fix setting and return to the initial screen.
20. After modifying the settings, turn off the module and then turn it on again to enter the working state.
Note: It is important to power the module with a separate power supply and not connect it to any other circuit. If the power supply is shared with other connections, ensure that the negative pole of the supply voltage and the detection voltage can be connected together. Also, make sure to set the module when no voltage is detected on the interface. If the interface has unsafe voltage, use an insulated object to press the buttons, and avoid using your hands.