To install the autoterm Flow 14D Hydronic Heater, follow the steps below:
1. Ensure that you have all the necessary parts and components listed in the "Contents of the installation kit" section of the manual.
2. Begin by mounting the heater itself (ASSY 4811 for 24V or ASSY 4816 for 12V) in a suitable location. Make sure it is securely mounted and positioned correctly.
3. Connect the wiring harness (ASSY 4393) to the heater, ensuring proper connections and routing.
4. Connect the control panel harness (ASSY 4394) and power supply harness (ASSY 73-01 for 24V or ASSY 1002 for 12V) to the heater and route them to the desired location for the control panel and power source.
5. Install the liquid pump harness (ASSY 76) and connect it to the heater.
6. Install the fuel pump (Dosing fuel pump P0636 for 24V or P0630 for 12V) and connect it to the fuel pump harness (ASSY 4071).
7. Install the exhaust pipe (ASSY 2321) and secure it properly.
8. Install the fuel tank (БТ13 ASSY 1065) and connect it to the fuel pump.
9. Install the air intake with silencer (ASSY 3043) and connect it to the heater.
10. Install the liquid pump (ASSY 2175) and connect it to the liquid pump harness.
11. Install any additional components and accessories as needed, following the instructions provided in the manual.
12. Secure all connections, hoses, and pipes using the provided clamps and fasteners.
13. Double-check all connections and ensure that everything is properly installed and secured.
14. Refer to the schematic of spare parts for any specific details or additional components that may be required for the installation.
Please note that this is a general overview of the installation process. For more detailed instructions and diagrams, please refer to the autoterm Flow 14D Hydronic Heater Instructions manual provided by the manufacturer.