Answer

Apr 17, 2025 - 03:22 AM
To install the red Smoke Alarms R240RC, please follow these steps:
1. Strip the Active/Neutral and Interconnect (if used) wires back to the strip length shown in the manual.
2. Connect the wires to the correct terminals on the base and ensure the terminal screws are fully tightened.
3. xxxx the mounting base onto the ceiling or wall using plugs and screws.
4. Clip the smoke alarm onto the base (if not already attached).
5. Engage the 10-year lithium battery by activating the on/off switch to the ON position before closing the smoke alarm to the base.
6. Turn on the mains power and check that the green and red LEDs function. The Green LED should illuminate steadily to show mains power is present. The Red LED will pulse every 40-60 seconds to indicate correct operation and that the backup battery is okay.
7. Press the Test/Hush button for 3 seconds to check if the alarm works.
8. Installation is not complete until both LEDs are functioning correctly.
Please note that the smoke alarm must be installed in accordance with the National Electrical Code and any local state legislation requirements. Failure to follow these instructions may result in a non-compliant installation.
For more detailed instructions and safety precautions, please refer to the instruction manual provided with the product.