According to the user guide, here are the steps to properly clean and maintain the Super Vac F124E Ventilator:
1. Disconnect the ventilator from the power source before performing any maintenance or repair.
2. Remove the ventilator guards to access the blade and inside housing.
3. Clean the ventilator blade and inside housing with mild detergent and water. Do not use abrasives, sharp instruments, or caustic solvents that may scratch or damage the aluminum alloy blade.
4. Inspect the inlet and outlet guards for damage or missing pieces. Replace damaged or missing guards before operating the ventilator.
5. After cleaning, position the guards with the rings to the outside, with the row of spot welds holding the rings on the bottom.
6. Ensure that all threaded fasteners are properly tightened.
7. Regularly inspect the power cord for any frayed, cut, or brittle insulation. Replace the power cord if necessary.
8. The motor of the ventilator is of heavy-duty ball bearing construction and does not require lubrication for the life of the motor.
9. If you encounter any issues or need further assistance, contact the authorized service center or Super Vacuum Manufacturing Company.
Please refer to the user guide for additional information and safety precautions related to the maintenance and repair of the Super Vac F124E Ventilator.