To install the ASK & TYR Set of the , follow these steps:
1. ASK Installation:
- Remove the acoustic panel where the luminaire should be mounted. Refer to the placement guide on page #3 for the correct location.
- Lift the luminaire through the ceiling opening, angling it to fit through.
- Connect the power cable WAGO connector to the Biocentric light control box.
- Ensure that the driver and luminaire are not covered with thermally insulating material.
- Place the luminaire flat in the ceiling framework.
2. TYR Installation:
- Remove the acoustic panel where the luminaire should be mounted. Refer to the placement guide on page #3 for the correct location.
- Using a sharp knife, make a hole in the acoustic panel to fit the cut-out diameter (93 mm) of the luminaire. You can use the cut-out template provided in the manual.
- Connect the power cable WAGO connector to the Biocentric light control box.
- Fold up the retention clamps and press the luminaire through the hole. Ensure that the clamps grip to the ceiling and that the luminaire or driver is not covered with thermally insulating material.
Please note that these instructions are a summary and it is important to refer to the complete instruction manual for detailed information and safety precautions. It is recommended to seek the assistance of a qualified electrician if you are not familiar with luminaire installation.