To power on the Avery Weigh-Tronix ZP2XX Series Scale, follow these steps:
1. Unpack the scale and ensure there is no damage to the packaging.
2. Remove the weight platter from the scale.
3. Remove the four black plastic shipping stops located between the top frame and the overload protection bolts.
4. Locate the plastic bag containing the necessary items, including screws (model ZP212 only), AC power supply, Legal for Trade sealing kit, and Extra Capacity labels.
5. Place the weight platter back onto the scale.
6. Plug in the AC adapter to the back of the unit.
7. Press the Power key to turn the scale on.
Please note that it is recommended to perform a field calibration using certified weights or modify the customer gravitational settings to meet your local requirements before using the scale. Additionally, you can use the dip switches on the rear of the scale to configure the interface protocol and com ports used to interface with your software program.
If you require further assistance or detailed instructions, you can access the user manual for the Avery Weigh-Tronix ZP2XX Series Scale by scanning the QR code provided or visiting the manufacturer's website at www.averyweigh-tronix.com.