To install the Anolis HP111 Ambiane Surface Mount fixture, follow these steps:
Step 1: Ceiling Opening
Create a standard mounting hole with a diameter of 100-105mm in the ceiling.
Step 2: Mounting of Control Unit
Place the control unit above the ceiling through the opening. Mount the control unit to the ceiling using two mounting holes and suitable fasteners.
Step 3: Primary Power Connection
Install a terminal block to the power cable (from Ambiance Power Rack or Ambiance Power HP) and connect it to the primary power socket of the control unit.
Step 4: Data Cables Connection (DMX or DALI)
For DMX connection, install terminal blocks on the DMX or DALI data cables and connect them to the control unit. Set the DIP switches to the appropriate positions based on your operation mode (DMX or DALI).
Step 5: Secondary Power Cable Connection 48V
Install a terminal block on the secondary power cable and connect it to the secondary power socket of the control unit.
Step 6: LED Unit Connection
Shorten the power/data cable of the LED unit to the required length. Strip the cable ends for wiring connection. Install a terminal block on the LED unit's cable and connect it to the control unit.
Step 7: Mounting of Luminaire
Insert the fixture into the ceiling mounting hole. Spread the holders and tighten them with an Allen key to secure the fixture firmly to the ceiling. The maximum thickness of the ceiling material should not exceed 20mm.
Step 8: Installation of Accessories (Ring Louver for 20° Reflector)
Insert the Ring Louver into the top frame of the fixture.