Answer

Apr 08, 2025 - 10:34 PM
To connect the LDT 000106 Connection Cable to the s88 feedback module, follow these steps:
1. If you are using the cable with the feedback module RM-88-N, RM-88-N-O, or RM-GB-8-N, remove the pin-pin plug from the cable.
2. Attach one socket of the cable to the 6-pole pin bar of the feedback module, ensuring that the single white wire corresponds with the white marking on the pin bar.
3. Attach the second pin-socket of the cable directly to the digital central unit or interface, or to another feedback module within the feedback line.
To connect the LDT 000106 Connection Cable to two Märklin or Viessmann feedback modules, follow these steps:
1. Remove the pin plug from the cable.
2. Insert the pin-socket connectors of the cable into the feedback modules, ensuring that the cable is directed towards the bottom. The white single wire should be located in the direction of the middle of the feedback module.
To connect the LDT 000106 Connection Cable to the Light-Display and Light-Power Module of the Light@Night and Light-DEC controls, follow these steps:
1. Insert the pin-plug connector of the cable into the 10-pole socket bar of the previous Light-Display or Light-Power Module, ensuring that the white single wire of the cable corresponds to the white marking on the module.
2. Connect the other side of the cable to the 10-pole pin plug of the next module, again ensuring that the white single wire corresponds to the white marking on the module.
Please refer to the provided manual for visual illustrations and additional information on connecting the LDT 000106 Connection Cable.