Answer

Apr 08, 2025 - 09:18 AM
To test AC voltage using the Laserliner 083 020 Universal Active Tester, follow these steps:
1. Ensure that the protective covers (5) are placed over the test prods for increased security against foreign touch.
2. Hold the base device (+) in your right hand and the second test prod (-) in your left hand.
3. Apply the test prods to the contacts to be tested, such as a line or socket.
4. If voltage is present, all the LEDs up to the voltage measured will light up, along with the positive and negative LEDs.
Note: It is important to make sure that the measuring circuit is closed by using both test prods. Using only one of the test prods is not sufficient for accurate testing.
For more detailed information and safety instructions, please refer to the Laserliner 083 020 Universal Active Tester's operating instructions manual.