Apr 05, 2025 - 10:58 AM
To install the Eltako FSR14SSR Noiseless 2-Channel Impulse Switch, it is recommended to hire a skilled electrician to ensure safety and avoid the risk of fire or electric shock. The switch should be installed in a location with a temperature range of -20°C up to +50°C and a relative humidity of less than 75%. The switch is designed for DIN-EN 60715 TH35 rail mounting and requires 1 module (18 mm wide, 58 mm deep).
To connect the switch to the Eltako-RS485 bus, use bus cross wiring and power supply with a jumper. If both relays of the FSR14 are switched on, a power of 0.4 watts is required. The switch has a rated switching capacity of 400 W for one contact and for the sum of the two contacts. Multiple devices can be connected in parallel to increase power.
For further details on the installation process and safety precautions, please refer to the Eltako FSR14SSR Noiseless 2-Channel Impulse Switch instructions manual.