To program the RFSG-1M Input Contact Converter, follow these steps:
1. Press the programming button on the actuator (e.g. RFSAI-61B-SL) for 1 second to activate the actuator into programming mode. The LED on the actuator will flash in a 1-second interval.
2. Press and hold the TEST button on the RFSG-1M for more than 4 seconds to automatically assign the RFSG-1M transmitter to the actuator.
3. If you want to finish programming mode, press the programming button on the actuator RFSAI-61B-SL for less than 1 second. The LED on the actuator will switch off.
Note: If you do not want to change the function of the controller, do not press the TEST button during the programming process.
For more detailed information, please refer to the "Programming" section in the inELS RFSG-1M Input Contact Converter Instruction Manual.