To install the FOAMit FI-WC-11AP High Concentration Foam Unit with All-Poly Fittings, follow these steps:
1. Remove all components from packaging.
2. Select a suitable area to mount the control box. It is recommended to mount it at a height of 6 feet or less, with the chemical suction lines reaching the bottom of the chemical container.
3. Attach the control box mounting feet to the back of the control box using the provided screws.
4. Mount the control box to the wall using the provided screws and plastic anchors. Drill holes for the anchors using a 5/16 inch drill bit.
5. Mount the hose hanger in a convenient location using the remaining two screws and anchors.
6. Attach the discharge hose assembly to the discharge hose barb and secure it with the larger hose clamp.
7. Connect the air inlet hose barb provided to the air inlet valve on the side of the control box. Attach a 3/8 inch air line from your air compressor to the air inlet hose barb and secure it with the smaller hose clamp.
8. Connect a water line to the water inlet fitting. Make sure to install a backflow preventer in the water line as required by local plumbing codes.
9. Insert the proper metering tips and connect the chemical intake lines to the inlet barbs. Use the included metering tip color chart to determine the appropriate metering tip based on the product and dilution rate.
10. Place the other end of each chemical intake line into a chemical container.