Answer

Mar 26, 2025 - 07:58 AM
To install the LEDone 5114179 MW Troffer Retrofit Kit, please follow these steps:
1. Safety Precautions:
- Read the installation instructions carefully before starting.
- Ensure that all wiring is done by a qualified electrician.
- Disconnect power before installing or servicing the fixture.
- Make sure the power is OFF before installation or maintenance.
- Only install the kit in luminaires that meet the specified construction features and dimensions.
- Do not make or alter any open holes in the enclosure of wiring or electrical components during installation.
2. Cleaning & Maintenance:
- Ensure the fixture is cool to touch before cleaning or maintenance.
- Clean the glass lens with a non-abrasive glass cleaning solution.
- Do not open the fixture to clean the LED, and do not touch the LED.
3. Troubleshooting:
- Check that the line voltage at the fixture is correct.
- Ensure the fixture is properly grounded.
4. Wattage & Color Temperature Selection:
- Select the appropriate wattage and color temperature for your needs.
5. Installation:
- Remove the existing fixture frame and clear out the inside of the existing housing.
- Install the bracket in the existing housing between the housing and tee-grid bar.
- Slide the bracket to both sides and secure it.
- Install the flat bottom side to one of the brackets, fix the supplemental supports, and connect the circuit.
- Close the retrofit fixture and secure the latch to ensure it is completely secure.
- Verify that the installation is complete.
6. 0-10V Dimmable Wiring:
- The universal voltage driver allows operation from 120V to 277V, 50/60Hz.
- For 0-10V dimming, follow the wiring instructions provided in Figure 7 of the manual.
- Connect the appropriate fixture leads to the corresponding supply leads and dimming leads.
- Ensure the ground wire from the fixture is connected to the supply ground, not the output ground.
- If the dimmable leads are unused, make sure they are properly capped.
For further assistance or more detailed instructions, please refer to the LEDone 5114179 MW Troffer Retrofit Kit Installation Guide.