Answer

Mar 25, 2025 - 09:28 AM
To adjust the wetness or dryness of the foam produced by the FOAMit FI-50N-SM 50 Gallon Smart Foam Unit, follow these steps:
1. While the unit is running and discharging product, locate the needle valve (NV14Y) on the unit.
2. Close the needle valve completely by turning it in a clockwise direction.
3. Open the needle valve in a counter-clockwise direction by turning it 2 complete turns.
4. Continue to open the needle valve in ¼ turn increments, allowing 30 seconds between adjustments, until the desired consistency of foam is achieved.
5. Release the air trigger to stop foaming.
Note: When you release the air trigger, the unit will shut off and depressurize. Foam that is already in the discharge hose may seep out, but no more foam will be created until you cover the air trigger again.
Please refer to the "Operation Instructions" section of the user manual for more detailed information on using the FOAMit FI-50N-SM 50 Gallon Smart Foam Unit.