To install and operate the FIRMAN 1210 50A Parallel Kit, follow these steps:
1. Ensure that both inverters are turned off and all electrical loads are disconnected before installing the parallel kit.
2. Align the inverters in the same direction, with a minimum spacing of 20 inches (50 cm) between them to prevent heat damage.
3. Remove the parallel outlet covers on each inverter and plug the parallel cable terminals into the parallel outlets.
4. Loosen the nuts on the grounding terminals of each inverter and attach the ground wire securely.
5. Turn on both inverters and make sure the green output indicator light comes on for each inverter.
6. Ensure that the ECO switch is in the same position on both generators before applying any load.
7. It is recommended to plug in devices with the largest output first and the smallest output last to prevent overloading the inverters. Do not exceed the maximum wattage rating of the inverters, parallel kit, and receptacles.
8. When finished, turn off the inverter generators per the owner's manual instructions and then disconnect the parallel kit.
Please refer to the FIRMAN 1210 50A Parallel Kit User Manual for more detailed instructions, including diagrams and parts lists. If you have any further questions or need assistance, you can contact the FIRMAN Product Service Department at 1-844-347-6261 or visit www.firmanpowerequipment.com for warranty service information or to order replacement parts or accessories.