Answer

Mar 21, 2025 - 12:34 PM
To install the dmf H3SO H-Series New Construction with Screws, follow these steps:
1. Before starting installation, read and understand the instruction manual completely for your safety.
2. Ensure that the power to the luminaire is turned off before installation to prevent electric shock.
3. Confirm that the electrical connection is in accordance with local and NEC standards and that the wiring is 120VAC.
4. Locate the fixture position and find the AC pigtail.
5. Align the housing to the bottom of the joist using alignment tabs.
6. Install both wood screws (factory installed) into the joist. Make sure the housing is securely held against the joist for proper installation.
7. Route the electrical wires through the wiring compartment using Romex tabs or knockouts.
8. Connect the hardwire adapter (included) to the housing electrical leads.
9. Mark the center fixture position on the drywall.
10. Cut an opening in the drywall according to the specified dimensions (H3SO: 3 1/2" [89mm], H4SO: 4 1/2" [114mm]).
11. Install the drywall. Note that the housing is compatible with ceiling thicknesses of 1/2" to 5/8".
12. Align the trim onto the module and snap it on.
13. Make the ground wire connection and attach the ground wire terminal (factory installed on the module) to the junction box following national and local electrical codes.
14. Connect the module connector.
15. Place the module into the housing and push the trim up until it is flush with the ceiling.
16. Press the trim to the ceiling and rotate it 1/4 turn to fully seat the trim.
Please refer to the instruction manual for any additional details or specific variations based on your installation requirements.