To properly install and connect the GYS WCU 1KW A Cooling Unit, follow these steps:
1. Choose a suitable location: Place the cooling unit on a flat surface with a maximum incline of 10 degrees. Ensure that the work area has sufficient ventilation and easy access to the control panel. The unit should be placed in a sheltered area away from rain or direct sunlight. Avoid using the unit in areas with metal dust.
2. Connect the cooling liquid: Fill the tank of the cooling unit with the recommended cooling liquid up to the maximum level indicated on the front of the unit. Do not fill below the minimum line to avoid warning messages. Only use the cooling liquid recommended by the manufacturer (ref. 052246). Using other coolants may damage the cooling system. Make sure the cooling unit is turned off before disconnecting the inlet and outlet hoses for the torch liquid.
3. Connect the power supply: The cooling unit requires a power supply voltage of 230V +/- 15%. Ensure that the power supply is compatible with the unit. Use the recommended fuse size of 5A. The unit is designed for single-phase power supply at 50 or 60Hz.
4. Check for proper functioning: Once the cooling unit is properly installed and connected, ensure that the ventilation holes are not blocked to allow adequate air circulation. The cooling unit features a default management system that allows the operator to diagnose errors and anomalies. Refer to the troubleshooting chapter in the instruction manual for guidance.
Please note that this is a general overview of the installation and connection process. For more detailed instructions and safety precautions, refer to the GYS WCU 1KW A Cooling Unit Instruction Manual.