To install the Novy 1821 Panorama Pro Hood, follow these steps:
1. Make sure that the power circuit to which the unit is connected is switched off.
2. Check that all the hood accessories are present in the packaging.
3. Pick up the hood only at the front side to prevent glass damage.
4. Check that all the hob parts are present in the packaging.
5. Determine the built-in height based on the height of the cabinet and worktop.
6. If the height is less than 760mm, a cut-out in the bottom plate of the cabinet needs to be performed.
7. Optionally, you can use the cooker hood kit 1821.400 for installation.
8. Measure the height left and right from the hob base plate to the supporting surface.
9. Set the height of the hood with the leveling feet.
10. Secure the leveling feet with the wrench.
11. Cut the vertical bend to the required size.
12. Slide the vertical bend into the outlet piece below the hood.
13. Make sure that the hood guides are fully inward and secure this position.
14. Lift the hood through the worktop cut-out in the housing and position it using the guides.
15. Secure the position of the mounting brackets on both sides of the hood.
16. Secure the position of the guides.
17. Level the hood at both the left and right using a spirit level.
18. Apply waterproof tape on the bottom of the induction hob.
19. Place the induction hob on the hood and align the cut-out in the hob glass with the side profiles of the tower.
20. Adjust the position of the induction hob until the spacing around the tower top glass and cut-out is even.
21. Secure the position of the hob on the hood with screws.
22. Adjust the height of the tower with respect to the top of the hob.
23. Connect the hob cable connector to the hood and connect the hood to the mains supply.
24. Connect the necessary fittings for recirculation or duct work.
25. Switch on the unit power supply circuit.
26. Remove the safety sticker from the tower.
27. Slide both lower collection trays into the hood.
28. Place the collection security in the hood and position it against the center of the tower.
29. Slide both upper collection trays into the hood.
30. Place both grease filters in the hood on the fall protection.
31. Verify the correct placement of the grease filters using the positioning tab.
32. Place the front glass on the hood tower and snap it into place.
33. Press the xxxx to re-initialize the tower.
34. Set the device in recirculation or duct out mode as desired.