To properly set up and inspect the METALTECH PJ-BAL Ultra-Jack System, follow these steps:
1. Prior to use, inspect the installation to ensure that the system is properly set up and ready to use.
2. Do not use the equipment if it is wet or frozen.
3. Lubricate the crank handle bushing with one or two drops of all-purpose lubricating oil as necessary. Do not use spray-type lubricants. Keep rubber surfaces clean of all lubricant.
4. Clean the rubber surface as necessary using a soft cloth and Isopropyl Alcohol (rubbing alcohol).
5. Use only Ultra-Jack products as part of this system. Do not use with other manufacturers' pump jacks, poles, or accessories.
6. Do not use with wood poles.
7. Poles must be secured with rigid triangular steel bracing at the top, bottom, and at points in-between in accordance with instructions.
8. Do not use without guardrails, mid-rails, toe boards, and/or a fall-arrest system. Ensure compliance with all applicable OSHA regulations and receive proper training.
9. Inspect all Ultra-Jack equipment before and after each use for any damage or deformation.
10. Inspect the rubber surface of the pole before and after each use for worn or damaged surface. Replace if necessary with Ultra-Jack replacement components.
11. When joining two poles, inspect splices to ensure that there is no gap between rubber surfaces.
12. The capacity of the pump jack scaffolding should not exceed two people or 500 lbs between any two poles.
13. Follow all local, national, or OSHA legislation that applies to the use and care of this product.
Please refer to the METALTECH PJ-BAL Ultra-Jack System Instruction Manual for more detailed instructions and safety guidelines.