Answer

Mar 13, 2025 - 03:39 AM
To install the SLOAN TRF 8936 Truflush Manual Electronic Flushometer, please follow the instructions provided in the TRF Electronic Dual Flush Wall Plate Installation Instructions, which can be downloaded from the Sloan website. Here is a step-by-step guide:
1. Start by turning off the water supply to the flushometer.
2. Remove the existing flushometer, if applicable, by disconnecting the water supply and unscrewing the mounting bolts.
3. Install the electroplated heavy-duty metal wall plate onto the wall using the provided screws.
4. Connect the water supply to the fixture connection on the flushometer, ensuring a secure and leak-free connection.
5. If you choose to hardwire the flushometer, consult the manual for the wiring instructions. Otherwise, insert four AA size batteries into the flushometer.
6. Mount the flushometer onto the wall plate, aligning the mounting holes and securing it with the provided bolts.
7. Turn on the water supply and check for any leaks.
8. Test the flushometer by pressing the tactile push buttons on the Sloan waterproof electronic PCB. The flush volume can be adjusted to either 1.6 or 0.8 gallons per flush using the dual flush feature.
For more detailed instructions and illustrations, please refer to the TRF Electronic Dual Flush Wall Plate Installation Instructions provided by Sloan.