Mar 13, 2025 - 02:29 AM
To adjust the interval for the KOLLER 230 8014B-S02 Electronic Control Box, you can use the DIP switch S4. The DIP switch is located on the control box and has two positions: "ON" and "OFF". In the interval mode, the aggregates (such as the pump, blower, and spotlight) will switch ON and OFF in a 2-second rhythm. Here is how the function works:
- Pressing the button for the first time: The aggregate will turn ON.
- Pressing the button for the second time: The aggregate will switch to interval mode, turning ON and OFF in the 2-second rhythm.
- Pressing the button for the third time: The aggregate will turn OFF.
- Pressing the button for the fourth time: The function will return to the first time, turning the aggregate ON.
By adjusting the DIP switch S4 to the desired position, you can control the interval of the aggregates' operation. Please refer to the user manual for more information and illustrations on how to locate and adjust the DIP switch.