To install the REZNOR 270615 Wind and Rain Hood Kit, please follow these steps:
1. Turn OFF the gas and disconnect the electric power.
2. Remove the screws that secure the fresh air inlet plate. Carefully pry off the plate, which is adhered with sealant, taking care not to damage the burner casing.
3. Apply a full circle bead of waterproof sealant to the inner flange of the outdoor air spigot.
Note: The screws securing the outdoor air spigot are installed in the same xxxx holes as the screws that secured the fresh air inlet plate.
4. Secure the outdoor air spigot to the burner casing using three spigot screws.
5. Apply a full circle bead of waterproof sealant to the mating surface of the wind and rain hood cover. Insert the cover into the outdoor air spigot.
6. Push the wind and rain hood cover fully home and drill a xxxx hole in each side of the outdoor air spigot.
7. Secure the wind and rain hood cover using two self-tapping screws installed in the holes drilled in step 6.
8. After the waterproof sealant has cured, turn ON the electric and gas and check the unit for proper operation.
Please note that this installation should be performed by a qualified service agency in accordance with the provided instructions and in compliance with all codes and requirements of authorities having jurisdiction. Improper installation, adjustment, alteration, service, and/or maintenance can cause property damage, injury, or death. The qualified agency performing this work assumes responsibility for this installation.
For more detailed information and safety instructions, please refer to the installation manual provided with the unit.