Answer

Mar 06, 2025 - 08:24 PM
To install the STAHL 255194 Breather, follow these steps:
1. Ensure that the breather is suitable for the application and meets the required explosion protection standards for your specific zone.
2. Choose the appropriate thread size (metric or NPT) and ensure that the breather is compatible with your enclosure.
3. Use the included connection thread seal and special fixture nut for installation.
4. Mount the breather on the enclosure in accordance with the manufacturer's specifications (IP67 and IP68 mounting).
5. Ensure that the breather is securely fastened and provides continuous pressure equalization between the inside and outside of the enclosure.
Features of the STAHL 255194 Breather:
1. Explosion Protection: The breather is certified for gas and dust explosion protection according to IECEx, ATEX, and EAC standards.
2. Temperature Range: It can operate in temperatures ranging from -60 °C to +130 °C, making it suitable for environments with temperature fluctuations.
3. Degree of Protection: The breather has an IP66 rating, providing protection against dust and water ingress.
4. Material: The breather is made of nickel-plated brass, ensuring durability and corrosion resistance.
5. Silicone-Free: The breather is silicone-free, reducing the risk of contamination or interference with other components.
6. Thread Options: It is available in both metric and NPT thread versions, providing flexibility for different enclosure types.
7. Worldwide Certification: The breather has certifications that are recognized globally, ensuring its compliance with international standards.
For more detailed information and specifications, you can refer to the STAHL 255194 Breather Owner's Manual available on the manufacturer's website (www.cmp-products.com).