Answer

Mar 06, 2025 - 08:17 PM
To install the Q-TRAN LALO-FLAT-OC Linear Fixture using the VHB adhesive mounting method, please follow these steps:
1. Surface Preparation: Clean the backside of the fixture and the surface area where the fixture will be installed using a 50/50 alcohol mix. Allow it to dry for 5 minutes.
2. Determine Fixture Placement: Decide on the location and positioning of the fixture on the desired surface. Make reference markings to indicate the fixture placement.
3. Apply VHB Adhesive: Peel back 0.5" of the VHB tape's protective film on one end and firmly press it onto the desired surface, avoiding air bubbles. Continue peeling the film and adhering the tape in small sections until the entire length is installed.
4. Position the Fixture: Remove the red film from the VHB adhesive and position the fixture in place according to the reference markings made earlier.
5. Remove Protective Film: Finally, remove the protective film from the surface of the fixture's lens.
Note: If you want to improve the bonding strength, you can apply a small amount of epoxy at each end of the fixture. Refer to the suggested epoxies table in the manual for suitable options. Follow the manufacturer's instructions for the epoxy application.
Please refer to the Q-TRAN LALO-FLAT-OC Linear Fixture Instruction Manual for additional installation methods and details.
Add New Comment