Answer

Mar 06, 2025 - 03:00 AM
To install the STAHL 8602C3 Large Rotary Actuator Increased Height, please follow the steps below:
1. Gather the necessary equipment: You will need the large rotary actuator increased height (Art. No. 227211), pushbuttons or other contact elements from the 8082 series, and any additional accessories you may require.
2. Ensure the actuator is suitable for your application: The 8602/3 series actuators are designed to withstand extreme conditions, with an application range of zones 1, 2, 21, and 22. They have explosion protection certifications such as IECEx, ATEX, UL, Inmetro, and more. Make sure the actuator meets the requirements of your specific application.
3. Prepare the installation area: Ensure the installation area is clean and free from any obstructions. The actuator has a degree of protection IP66, meaning it is dust-tight and protected against powerful water jets.
4. Mount the actuator: The actuator has a diameter of 65mm and is designed for increased height installation. It should be mounted using the provided thread type and tightened with a torque of 3 Nm. Refer to the technical drawings for the exact mounting details.
5. Connect contact elements: The actuator can actuate up to four contact elements from the 8082 series. Connect the desired contact elements according to your application requirements. The actuator also has coding options for key switches and rotary switches, allowing you to adjust the functions as needed.
6. Verify proper installation: Once the actuator and contact elements are installed, ensure everything is securely fastened and functioning correctly. Test the actuator to ensure it operates smoothly and without any issues.
Please note that this answer provides a general overview of the installation process. For detailed instructions and specific information, it is recommended to refer to the official installation guide provided by R. STAHL Schaltgeräte GmbH.
Add New Comment