Answer

Mar 05, 2025 - 11:48 PM
Installation:
1. Open the safety lock buckle on the current transformer.
2. Thread the current-carrying conductor through the split core.
3. Close and fasten the safety lock buckle securely.
Wiring:
1. Connect the audio connector output of the current transformer to your measuring instrument or monitoring device.
2. The lead type output can be customized to your desired length.
3. Ensure that the load resistance is within the specified range for accurate measurements.
4. Refer to the wiring schematic diagram provided in the manual for a visual representation of the connections.
Please note that the YHDC SCT013 Split Core Current Transformer is available in various models with different input currents and output voltages. Choose the appropriate model based on your specific requirements.
For further technical information and specifications, please refer to the provided manual.