Answer

Mar 05, 2025 - 02:30 AM
Wiring and installation of the SECOMP 25168490 ROLINE Cat.6A (Class EA) socket, 2x STP, flush-mounted can be done by following these steps:
1. Gather the necessary tools: You will need a screwdriver for slotted head screws (size 6x0.8), an LSA+ tool, and screws (size 1).
2. Prepare the pairs: Presort the pairs according to the color code mentioned in Figure 3 of the installation guide.
3. Connect the wires: Ensure that the pairs are crossed as near as possible to the ground. Use the LSA+ tool to connect the wires to the appropriate terminals on the socket. The socket can be wired up in 4x90° steps, allowing for flexibility in installation (up and down, left and right).
4. Secure the socket: Fasten the cover plate, adapter plate, and mounting plate using the screws (size 1) and the screwdriver.
By following these steps, you should be able to successfully wire and install the SECOMP 25168490 ROLINE Cat.6A (Class EA) socket, 2x STP, flush-mounted. For further details and visual guidance, please refer to the installation guide provided with the product.