Answer

Mar 05, 2025 - 02:18 AM
To clean the coil of the GE NS18HM Variable Speed High-Efficiency Split Heat Pump System, follow these steps:
1. Turn off the power to the unit by switching off the circuit breaker or disconnecting the power supply.
2. Remove the individual metal louvered panels on the cabinet to access the coil.
3. Use a soft brush or vacuum cleaner with a brush attachment to gently remove any dust or debris from the coil. Be careful not to damage the fins.
4. If necessary, you can use a mild detergent mixed with water to clean the coil. Apply the solution to the coil using a soft brush or spray bottle, and then rinse it off with clean water.
5. Allow the coil to dry completely before reassembling the unit.
6. Once the coil is clean and dry, reinstall the metal louvered panels on the cabinet.
7. Turn on the power to the unit and ensure it is operating correctly.
Note: It is recommended to clean the coil at least once a year or as needed, depending on the operating conditions and environment. Regular maintenance and cleaning of the coil will help ensure optimal performance and energy efficiency of the heat pump system. For more detailed instructions and safety precautions, refer to the instruction manual provided with the product.