Answer

Mar 05, 2025 - 02:12 AM
To connect the YANDINA C200 Two Bank Battery Combiner to your batteries, follow these steps:
1. Connect the NEGATIVE terminal (left of 3) to either battery negative or any convenient negative terminal block.
2. Connect two 6-gauge or smaller RED cables between the Combiner and the positive terminals of the batteries. Use a MINIMUM of 6 feet. You can use combinations like 3+3 or 5+1. Longer cables are also acceptable. If the distance between the Combiner and the batteries is more than 12 feet, you can use a gauge heavier than 6.
3. The connections do not have to be made right on the battery terminals, but any wire or cables between the battery and the Combiner must be heavy enough to carry the Combiner current in addition to any existing loads.
Make sure the second Combiner connection is not touching ground when you connect the first since the Combiner sometimes closes momentarily when initially connected.
For more detailed information and illustrations, refer to the YANDINA C200 Two Bank Battery Combiner Instruction Manual.