Answer

Mar 04, 2025 - 09:24 PM
To install the LARK 85600 Flush Mount fixture, follow these steps:
1. Find a clear area in which you can work and unpack the fixture and glass from the carton.
2. Carefully review the instructions prior to assembly.
3. To begin, remove the mounting plate (A) from the backplate (C) by removing the screws (E) located on the side of the backplate (refer to Drawing 1).
4. Attach the mounting bracket (A) to the junction box using two 8-32 screws (not provided) or the screws from the previously installed mounting strap or plate. Make sure the threaded holes are on the side when installing the mounting plate, and ensure the plate is plumb by placing a level across the top. Adjust the plate and tighten the screws to secure the mounting plate.
5. Make all necessary wiring connections by following the instruction sheet (IS-18) provided. Ensure you read the wiring and grounding instructions (IS-18) and any additional directions. Turn off the power supply during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements.
6. After making all electrical connections, slip the backplate (C) over the mounting strap (A) and align the holes in the side of the backplate (C) with the threaded holes on the side of the mounting strap (A).
7. Thread in the screws (E) that were removed earlier to secure the backplate to the mounting strap.
8. Slide the LED cover (3) over the LEDs (2).
9. Use screws (1) to secure the end-caps (4).
10. The fixture can now be powered on.
Please refer to the complete instruction manual for additional details and illustrations.