Answer

Mar 02, 2025 - 07:10 PM
To adjust the temperature on the Perlick BC24 24 Inch Stainless Steel Horizontal Flat Top Bottle Cooler, follow these steps:
1. Locate the digital temperature control on the front face of the bottle cooler, above the condensing unit housing.
2. Press the "SET" button to display the current setpoint temperature.
3. Use the "+" and "-" buttons within 15 seconds to change the setpoint temperature to your desired value.
4. Press the "SET" button again to confirm the modification.
The default temperature setpoint for the standard temperature (RT) model is 38°F (3.3°C). The adjustable setpoint range for the standard temperature (RT) model is 34 - 40°F (1.1 - 4.4°C). Please refer to the manual for temperature specifications of other models.
Note: The condenser fan motor turns off and on with the compressor, while the evaporator fan motor runs continuously.