To install the GIRA 1149 02 Smoke Alarm Device Basic Q, follow these steps:
1. Select the installation site: Choose a location that complies with the specifications of DIN EN 14676. It should be as close as possible to the center of the ceiling, at least 50 cm away from walls, lights, and other obstructions. Install one smoke alarm device per room (maximum 60 m2 area) and avoid installing it near heat sources.
2. Mounting plate installation: Install the mounting plate according to the instructions provided.
3. Activation: Remove the guard from the activation slider (grey) and slide it into the guide completely to activate the smoke alarm device.
4. Place the smoke alarm device: Place the activated smoke alarm device onto the mounting plate and lock it by turning it clockwise. Ensure that the activation slider is properly inserted into the smoke alarm device to prevent tilting.
5. Function test: After installation, perform a function test by pressing and holding the function button (grey) for approximately 4 seconds. A loud signal tone will be emitted, and the ring indicator will flash. Release the function button to mute the signal tone and turn off the ring indicator.
Please note that the installation and mounting of electrical devices should only be carried out by qualified electricians. For more detailed information and guidance, refer to the GIRA 1149 02 Smoke Alarm Device Basic Q Instruction Manual.