Answer

Mar 01, 2025 - 05:39 AM
Installation of the CORGI 72401 22mm Inline Magnetic Central Heating Filter is relatively easy. Here are the steps to install the filter:
1. Determine the appropriate position for installation: The filter should be installed on the return pipe of the central heating system, preferably close to the boiler. Ensure that there is enough space for the filter and easy access for maintenance.
2. Shut off the central heating system: Before installing the filter, make sure to shut off the central heating system and allow it to cool down.
3. Prepare the pipework: Cut the return pipe of the central heating system at a suitable location to accommodate the filter. Ensure that the pipe is clean and free from debris.
4. Install the filter: Connect the filter to the cut ends of the pipe using the provided compression fittings. Ensure a secure and leak-free connection. The filter should be installed in the correct water flow direction, as indicated by the arrow on the filter body.
5. Secure the filter: Use suitable brackets or straps to secure the filter in place. Ensure that the filter is properly aligned and supported.
6. Open the valves: Open the two ball valves on the filter to allow water flow through the system. Check for any leaks and tighten the fittings if necessary.
7. Check the system: Once the filter is installed, check the entire central heating system for any leaks or issues. Ensure that the system is functioning properly before turning it back on.
For more detailed instructions and illustrations, please refer to the CORGI 72401 22mm Inline Magnetic Central Heating Filter Instruction Manual provided with the product.