To install the Ganter Norm GN 9154 Position Indicators, follow these steps:
1. Before installation, create a locating hole on the machine side for the torque limiting contact point, as shown in the drawing provided in the manual.
2. If needed, use the mounting adaptor bushings GN 952.1 to adapt the hollow shaft of the position indicator to fit the spindle. These bushings have a bore of 14 H7.
3. If you want to reduce the diameter of the hollow shaft while mounting a control xxxx , you can use control knobs GN 957, which combine both functions in a single component.
4. Mount the position indicator by inserting the torque limiting contact point into the bore hole to stabilize the housing. Secure the hollow shaft to the spindle using the grub xxxx .
5. After adjusting, you can use clamping plates GN 9054.6 to clamp and secure the spindles.
For more detailed instructions and diagrams, please refer to the operating instruction manual for position indicators GN 9154, which is included with every position indicator and can also be downloaded from the Ganter Norm website in the Service section.
Note: It is important to ensure a safe distance of at least 200 mm between the control unit and high-powered components such as motors or converters to avoid any disruptions or interference in the wireless communication between the position indicators and the control unit.