To replace the coning blade on the Swagelok Manual Coning and Threading Tool, follow these steps:
1. Loosen the two 1/4 in. set screws using the 1/8 in. hex key.
2. Remove the blade holder from the housing.
3. Carefully remove chips using a chip brush.
4. Loosen the four #10 set screws using a 3/32 in. hex key.
5. Remove the coning blade from the blade holder.
6. Remove chips from the coning blade pocket in the blade holder using a chip brush.
7. Install the new coning blade for the tube diameter and pressure to be coned. Check the ordering number marked on the coning blade to ensure the proper coning blade is being installed.
8. Tighten the two #10 set screws opposite the coning face of the blade first to set the coning insert properly.
9. Tighten the other two #10 set screws.
10. Align the blade holder chip slots with the 1/4 in. set screws in the housing.
11. Slide the blade holder into the housing.
12. Tighten the two 1/4 in. set screws while making sure they engage with the countersinks in the blade holder.
Make sure to follow all safety precautions and refer to the Swagelok Manual Coning and Threading Tool User Manual for detailed instructions and illustrations.