Answer

Feb 28, 2025 - 10:27 AM
To address the DALI-2 dimming actor AC 85787-V2, you will need an active DALI master unit as the dimming actor itself does not have its own active DALI CPU. Here are the steps to address the dimming actor:
1. Connect the DALI-2 dimming actor AC to the DALI bus line in a de-energized state.
2. Connect the dimming actor to the 230 V AC mains voltage.
3. Use the active DALI master unit to carry out the DALI addressing process.
Please note that the DALI addressing process may vary depending on the specific DALI master unit you are using. Refer to the user manual of your DALI master unit for instructions on how to address DALI devices.
It is important to follow the safety instructions provided in the manual and have a professional electrician complete the installation to ensure compliance with European safety directives.
Add New Comment