To configure the e-peas AEM00330 Battery Charger, follow these steps:
STEP 1: AEM00330 Configuration
Refer to the datasheet for information on the jumpers and connectors. Use the jumpers SRC_LVL_CFG[x] to define the source voltage regulation. Use the jumpers STO_CFG[x] to define the storage element protection levels. Use the jumpers LOAD_CFG[x] to define the LOAD voltage. Use the jumper to set the dual-cell supercapacitor BAL feature. Use the jumpers to enable the different modes. Use the jumper to select the rectifier.
STEP 2: Connect the storage element
Use the xxxx connector or JST connector to connect the storage element to the charger.
STEP 3: Connect the load to LOAD
Connect the load to the LOAD connector using the appropriate connectors or cables.
STEP 4: Connect the harvester
Connect the harvester or energy source to the appropriate xxxx connector for the source.
STEP 5: Check the status
After configuring and connecting all the necessary components, check the status of the battery charger to ensure it is functioning correctly. Refer to the user guide or datasheet for information on how to check the status.
For more detailed information and specific instructions, please refer to the e-peas AEM00330 Battery Charger User Guide available on the e-peas website at www.e-peas.com.