Answer

Feb 27, 2025 - 09:42 PM
To set the delay time for the PNi K80 Power Supply Control, you need to follow the specifications of the lock or electromagnetic closure you are using. For locks and electromagnetic closures with retention, the power source should be set with a delay of 0 seconds to prevent burning. For locks and electromagnetic closures without restraint, the timing should be set according to the specifications of the lock to prevent damage.
It is important to consult the technical documentation of the specific lock or electromagnetic closure before connecting it to the power source. This will ensure correct connection and prevent irreparable damage to the equipment.
Please note that the power source can also receive the opening command on the Control + and Control - connectors with an energized pulse type command with a voltage between 6-32V DC (<1 second, respecting the polarity).
For further information and guidance, please refer to the PNi K80 Power Supply Control User Manual available at the following link: [link to the manual]