To install the PUMOTIX PLL005-G3 Sensor Edge Finder, follow these steps:
1. Ensure that the CNC machine is turned off and de-energized before making any connections.
2. The sensor is designed to be installed into the spindle collet with a diameter of 6 mm.
3. Solder the wires according to the diagram shown in Figure 2 of the manual.
4. Make sure that the operation program of the CNC machine does not turn on the spindle while measuring.
To calibrate the sensor, follow these steps:
1. After assembly, the sensor is calibrated and centered. However, if there is a strong mechanical impact or prolonged use, the alignment procedure may need to be repeated.
2. Hold the sensor in the spindle and fix a test indicator.
3. Rotate the spindle at a low speed and observe the deflection amplitude of the stylus indicated by the test indicator.
4. Use a 2.5 mm hex wrench to turn the adjusting screws on the bottom of the sensor to eliminate any deviation. Both tightening and loosening should be used while adjusting.
5. Follow the alignment process shown in Figure 4 of the manual.
Please note that the manual provides detailed diagrams and instructions for installation and calibration. It is important to follow the instructions carefully to ensure proper installation and calibration of the sensor.
For any further assistance or technical support, you can contact PUMOTIX directly at the provided contact numbers or visit their website at pumotix.com.