Answer

Feb 26, 2025 - 05:55 AM
To configure port isolation on the FS S3150-8T2FP PoE+ Series Switches, you can follow the steps below:
1. Enter the global configuration mode by typing "config" in the command line interface.
2. Enter the configuration mode for the port you want to configure by typing "interface g0/1" (replace "g0/1" with the actual port number).
3. Enable or disable port isolation by typing "[no] switchport protected" command. Use "switchport protected" to enable port isolation and "no switchport protected" to disable it.
4. Exit the port configuration mode by typing "exit".
5. Exit the global configuration mode by typing "exit".
Note: The above steps are for configuring port isolation without using groups. If you want to configure port isolation based on groups, please refer to the manual for the specific commands and steps.
For more detailed information and additional configuration options, please refer to the "FS S3150-8T2FP PoE+ Series Switches Port Additional Characteristics User Guide" provided by the manufacturer