Installation and usage of the are relatively straightforward. Here is a step-by-step guide:
1. Mounting the Patch Panel:
- Determine whether you want to mount the patch panel vertically or horizontally.
- Use the included 89B mounting bracket to secure the patch panel to the desired location on the wall.
- Ensure that the mounting surface is sturdy and can support the weight of the patch panel.
2. Wiring the Patch Panel:
- Before wiring, make sure to keep less than 1cm "un-twist" of each pair, as specified by ANSI/TIA and ISO standards.
- Identify the numbered ports on the front of the patch panel.
- Prepare your Cat5e UTP cables by stripping off the outer jacket and untwisting the pairs.
- Insert each wire into the corresponding numbered port on the rear of the patch panel.
- Use a punch-down tool to firmly press down on the wires, securing them in the rear 110 IDC punch-down terminals.
- Repeat this process for each port, ensuring proper color-coding and alignment.
3. Labeling and Organization:
- Once all the cables are punched down, use the included labels to mark each port for easy identification.
- You can use a label maker or write directly on the labels.
- This step is crucial for efficient cable management and troubleshooting.
4. Testing and Verification:
- After completing the wiring and labeling, it is recommended to test each port using a cable tester or network analyzer.
- This will ensure that the connections are properly terminated and functioning correctly.
For any additional information or troubleshooting, you can refer to the Simply45 S45-2512 12 Port Loaded Patch Panel manual or contact Simply45 directly through their phone or website provided.