To access the setup pages for the CONTROLbyWEB X-422 Davis Weather Suite Controller, follow these steps:
1. Connect the module to power using Power over Ethernet (POE) and/or a 9-28VDC power supply.
2. Connect the module to a network.
3. Set up your computer on the same network as the module by setting the IP address of the computer to 192.168.1.50 with a netmask of 255.255.255.0.
4. Open a web browser on your computer and type the following into the address bar: http://192.168.1.2/setup.html
5. Log in to the setup pages using the default username: admin and default password: webrelay (all lowercase).
6. In the setup pages, go to the Network tab and set the permanent IP address for the module.
7. Restart the module by removing power and then re-applying power.
8. After the module restarts, set your computer back to its original network settings.
9. Access the module at its new IP address.
Please note that these instructions are based on the information provided in the user guide for the CONTROLbyWEB X-422 Davis Weather Suite Controller. For more detailed instructions and troubleshooting, refer to the user guide available at www.ControlByWeb.com/support/.