The requires specific wiring for proper installation. Here is a breakdown of the wiring positions and wire models recommended by the manufacturer:
1. Power Supply - Access Controller: Use RVV2*1.0 wire with a distance of less than 100 meters.
2. Access Controller - Reader: Use RVV4*0.5 wire with a distance of 60 meters maximum, not exceeding 100 meters.
3. Access Controller - Electric Lock: Use RVV4*1.0 wire with door-magnet feedback and a distance of less than 150 meters.
4. Access Controller - Exit Button: Use RVV2*0.5 wire with a distance of less than 200 meters.
5. Access Controller - IR Alarm: Use RVV2*1.0 wire with a distance of less than 200 meters.
6. Access Controller - Sound-light Alarm: Use RVV2*1.0 wire with a distance of less than 150 meters.
7. RS485 Communication Cable: Use RVVP2*1.0 wire with a distance of less than 1000 meters. The shield layer should be connected to ground.
8. TCP/IP Communication Cable: Use CAT-5 cable with a distance of less than 100 meters.
Please note that these wiring recommendations are based on the manufacturer's specifications. It is important to follow these guidelines to ensure proper functionality of the access control system.
For more detailed information and diagrams, please refer to the VISION VS-AXESS-4ETL Commercial Access Control User Guide provided by the manufacturer.