Answer

Feb 24, 2025 - 07:48 AM
To adjust the settings on the Whale SDS081T Switch Connect Transformer, follow these steps:
1. Locate the jumpers on the base of the transformer.
2. Move the jumpers to connect pairs of contacts to suit your specific installation requirements.
- Setting 1: Mixer / Electric (M / E)
- M: Select this setting for a mixer valve shower installation.
- E (Default Setting): Select this setting for an electric shower installation.
- Setting 2: Flow Setting
- ≡ (Default Setting): With Setting 1 set to E, the pump runs at the optimum speed to remove water delivered by a healthcare electrical shower while keeping gulley noise to a minimum.
- -0.5, +0.5, +1.0, +2.0, +3.0 Ltrs/min (approx.): These settings are used in conjunction with Setting 1, E or M, to enable the pump speed to be fixed faster or slower to deal with the maximum flow from any shower up to 12 ltrs/min while keeping gulley noise to a minimum.
- Setting 3: Off Delay (10, 30 Seconds)
- 10 Seconds (Default Setting): Recommended for electric shower and mixer shower installations.
- 30 Seconds: Suitable for installations where water is slow to drain into the gulley.
Note: It is important not to make the pump run faster than necessary, and default settings should normally be used.
For more detailed information and illustrations, please refer to the Whale SDS081T Switch Connect Transformer User Guide.