To connect the Phocos Pytes Inverter to the battery and set up communication with the Pytes E-BOX battery, please follow these steps:
1. Connect the power cables between the inverter and the battery or the busbars.
2. Use a custom Ethernet cable for communication between the Pytes E-BOX battery and the Phocos Any-Grid™ series inverter.
3. Refer to Figure 2.1.2.1 in the manual for the pin assignment of the Phocos Any-Grid™ series inverter. Connect the cables as follows:
- Plug one end of the cable into the RS485 port of the Pytes E-BOX battery.
- Plug the other end of the cable into the Phocos BMS Port on the inverter.
To program the inverter, follow these steps:
1. Press and hold the button for 3 seconds to enter the settings mode.
2. Use the button to navigate between the settings menus. Once you have selected a menu, press the button to confirm the selection or exit without confirmation.
3. Select menu option 05 (Battery type) and set the value to "RS-485" as shown in Figure 2.1.2.5.
For more detailed settings, such as Grid Setup and PV Setting, please refer to the Phocos AnyGrid Hybrid inverter manual.
Please note that the above instructions are a summary and it is important to consult the official Phocos Pytes Inverter user guide for complete and accurate information.