To properly terminate the Simply45 S45-1700P ProSeries Pass-Through RJ45 modular plugs for UTP LAN cables, please follow these step-by-step instructions:
1. STEP 1: Align the 2 posts on the Cap45® with the 2 holes on the front of the plug.
2. STEP 2: Push the posts into the plug until the Cap45® is snug to the plug body.
Best Practice Termination Guide:
The Simply45 S45-1700P ProSeries Pass-Through RJ45 modular plugs are designed to provide greater electrical conductivity and improved cross-talk performance for LAN cable applications. Follow these instructions for improved termination performance:
Wiring Chart:
- If using Cat6 UTP cable, trim the center spline/pair separator as close to the cable jacket as possible without nicking any of the wire conductors.
- Make sure each wire conductor is straight. It is recommended to use the Simply45 Adjustable LAN Cable Stripper that has a wire straightener comb on the top.
- Straighten and align the wires to the correct alignment pattern (Type A or B). The B pattern is commonly used. Trim the wire ends straight before inserting them into the load bar.
- The S45-1700P plug uses a Hi/Lo wire layout. Insert the pattern-aligned wires into the rear of the plug and push them out through the front of the plug. Verify that the wires are still in the correct pattern alignment.
- Push the plug down and over the cable jacket. The cable jacket should come to the horizontal line underneath the plug. This minimizes the length of the untwisted wires, improving signal integrity and reducing crosstalk interference.
- Insert the loaded plug into the crimping socket on the Simply45 crimp tool, ensuring it is fully inserted.
- Firmly and in one quick and steady motion, fully compress the crimper handles until it releases. The Simply45 crimpers are ratcheted, meaning the tool handles will not release until the full crimping cycle is completed.
- Inspect the terminated plug to ensure wires have been properly trimmed. Then attach the Cap45® to the plug following the instructions provided.
By following these instructions, you can properly terminate the Simply45 S45-1700P ProSeries Pass-Through RJ45 modular plugs for UTP LAN cables.