Answer

Feb 21, 2025 - 10:33 PM
To program the BFT Rigel 6 QRG Universal Control Unit to open and close your gate, follow these steps:
1. Make sure you have read and understood the installer warnings in the main instruction document provided with the unit.
2. Connect the motor supply cables to the blue connectors labeled 10, 11, 12 for Motor 1 and 14, 15, 16 for Motor 2.
3. Position the gates in the closed position, unless using specific gate models that require a different position.
4. Navigate to the Autoset menu by pressing the OK button twice rapidly, then select "Para" (parameters), "Logic," "Radio," and finally "Default."
5. Launch the Autoset by selecting "Program panel to Autoset" and pressing OK. The motors will open one by one. When the open position is reached for Motor 1, press the OK button 3, 2, 1. Then, Motor 2 will open, and when its open position is reached, press the OK button 3, 2, 1.
6. With the gates showing as open, press the OK button 3, 2, 1. Motor 2 will close first, followed by Motor 1. When the closed position is reached for Motor 1, press the OK button 3, 2, 1.
7. With the gates showing as closed, press the OK button 3, 2, 1. Motor 1 will open followed by Motor 2. From the open position, Motor 2 will close first, followed by Motor 1. Once the process is completed, "OK" will be displayed.
If the motors try to close at the launch of the Autoset, you may need to swap the motor cables for Motor 1 (10 and 12) and Motor 2 (14 and 16).
Please note that these instructions are a summary and should be used in conjunction with the supplied user guide for complete and accurate programming information.